ISO section of this standard contains the common test methods to support the functional requirements for small-bore connectors. The other parts document the design and dimensions of small-bore connectors according to their specific application categories and provide a framework for testing connectors of different medical applications against each other to ensure non-interconnectability.
ISO section 'Connectors for breathing systems and driving gases applications' and ISO section 'Connectors for urethral and urinary applications' are still under development by the International Organization for Standarization. In many instances, testing requirements are beyond the test method parameters set out in a standard. Alongside our standard testing services, our expert team is able to develop a custom testing program to meet your specific testing requirements and resolve and design or functionality issues you might have.
Please note: The information outlined above is to be used as a reference. Please refer to the appropiate competent standards agency in your country for full details and implementation of EN ISO Minor Outlying Islands U. By providing your personal information e. These might include purchased products such as market reports and conference places, testing or consulting services as well as digital resources such as whitepapers, webinar and brochures.
Smithers is committed to ensuring the information we collect and use is appropriate for this purpose, and will process collect, store and use the information you provide in a manner compatible with the governing data protection laws.
Smithers will endeavor to keep your information accurate and up-to-date, retaining it only for as long as required. A Smithers member company may on occasion transfer your personal information to another Smithers member company, in some cases outside the European Economic Area.
Smithers member companies are obligated by agreement amongst themselves to protect such information and comply with applicable privacy laws.
Smithers will not pass on your information gained through an engagement without your consent. Smithers follow strict procedures to ensure your personal and financial information remain secure. To prevent unauthorised access or disclosure of your information, we have put in place stringent security and best practice processes to ensure your information is protected online.
Smithers will retain personal information collected from you where we have an ongoing legitimate business need to do so. Smithers will only retain your personal information for as long as necessary to fulfil the purposes for which we collected it and in accordance with the time periods found in our Data Retention Policy. At any point while we are in possession of or processing your personal data you can exercise all of the rights available to you under the governing data protection law.
You can view these rights in full on our Privacy Notice. Type: International Standard. ICS: ISO specifies general requirements for small-bore connectors, which convey liquids or gases in healthcare applications. These small-bore connectors are used in medical devices or accessories intended for use with a patient.
ISO also specifies the healthcare fields in which these small-bore connectors are intended to be used. It is expected that when the relevant particular medical device standards are revised, the risks associated with changing to the new small-bore connectors as specified in the ISO of standards will be considered. It is understood that small-bore connector systems cannot be designed to overcome all chances of misconnection or to eliminate deliberate misuse.
In a coronary care unit there are as many as 40 Luer connectors on the medical devices used with a single patient. It does not specify requirements for the medical devices or accessories that use these small-bore connectors. But mix-ups with connectors that mean the wrong product is delivered can have catastrophic consequences.
Accept and continue Learn more about the cookies we use and how to change your settings. This International Standard also specifies ieo healthcare fields in which these small-bore connectors are intended to be used. It is expected that when the relevant particular medical device standards are revised, requirements for small-bore connectors as specified in the series of standards will kso included.
Connectors for neuraxial applications — Part 7: This document provides the methodology to assess non-interconnectable characteristics of small-bore connectors based on their inherent design and dimensions in order to reduce the risk of misconnections between medical devices or between accessories for different applications as specified in this document as well as those that will be developed under future parts of the ISO series.
Small-bore connectors as specified in this International Standard are non-interconnectable with: These healthcare fields include, but are not limited to: Life izo A standard is reviewed isp 5 years 00 Preliminary.
A new standard for connectors with intravenous or hypodermic applications has just been published, complementing the series The intention is to provide accurate information; regardless; errors may exist in the supplied information.
Subsequent parts of this series of are expected to include requirements with regard to the connectors used in different application categories.